TYAS290 aircraft air vehicle is to directly start the large engine of the aircraft through the output of low pressure and large flow compressed air, applicable models: Boeing 707, 717, 727, 737 series (-100, -200, -300, -400, -500, -600, -700, -800, -900), 757, 767, 747 series, part of the B777, DC8, DC9, DC10, MD80 series (81,82,83, 83) 88), MD90, MD11, Airbus A320 family (A321,A320,A319,A318), A300, A310, A330, that is, all models except the GE90 engine.
1. Protection of aircraft:
Mechanical pressure relief valve
When the gas supply system pressure exceeds 50psi, the safety valve operates and deflates to maintain the system gas supply pressure.
Air supply pressure protection switch
When the pressure of the gas supply system exceeds 44psi, the pressure switch acts to implement the gas supply protection.
Unit protection cut off in starting mode
When the "select switch" on the operating panel is pressed to the "Aircraft Start" position, all protective functions of the unit are removed.
Aircraft air supply connection with screen
2, the protection of the unit:
High engine water temperature protection
When the coolant temperature in the radiator exceeds 103 ° C, the unit automatically stops, and the engine water temperature indicator on the operation panel lights up.
Low engine oil pressure protection
When the engine oil pressure is lower than 270kPa, the unit will automatically stop, and the engine oil pressure low indicator on the operation panel will light up.
Engine cooling low level protection
When the engine coolant level is low, the unit automatically stops and the coolant level low indicator on the operation panel lights up.
Compressor oil temperature high protection
When the compressor oil temperature exceeds 76 ° C, the unit automatically stops, and the compressor oil temperature indicator on the operation panel lights up.
Low compressor oil pressure protection
When the compressor oil pressure is lower than 50kPa, the unit automatically stops, and the compressor oil low pressure indicator on the operation panel is on.
High protection of compressor gas supply temperature
When the air supply temperature of the compressor is higher than 220 ° C, the unit automatically stops, and the high air supply temperature indicator on the operation panel lights up.
Charge protection
When the charging system fails, the charging protection indicator on the operation panel lights up.
Emergency shutdown
There is an emergency stop button on the operation panel. When there is an emergency, press the button to forcibly shut down the engine.